Abstract
Collagen is the most abundant protein in the human body, and therefore studying its early-stage formation and mechanics is of high significance. However, the collagen monomer only measures 300nm long and 1.5nm wide, making it challenging to quantify using traditional microscopy. In addition, collagen fibrils (combinations of collagen monomers) typically only reach between 20-500nm in diameter, furthering the challenge of observing early-stage collagen formation.
In this talk, we will focus on two methods our lab has developed to more accurately quantify collagen optically below the diffraction limit. These include:
1. Single collagen molecule quantification using epi-fluorescence microscopy. This is a technique we use to quantify the number of AlexaFluor tags on a single collagen molecule, which we can then use for orientation/other quantitative purposes.
2. Interferometric confocal reflectance microscopy (I-CRM) for collagen fibril diameter quantification (both on glass and in solution). This is a multi-wavelength local interference technique that can quantify collagen fibril diameters below 50nm. We will talk about both on-glass and in suspension scenarios.
Speaker Bio
Eric Hall is a 4th year Electrical Engineering PhD student in the Optical Sciences Laboratory at Northeastern University, working with Dr. Charles DiMarzio and Dr. Jeffrey Ruberti. He holds a BS in Biomedical Engineering from Worcester Polytechnic Institute (WPI), and a MS in Electrical and Computer Engineering from Northeastern University. His main focus is on quantifying collagen below the diffraction limit, using techniques such as fluorescence, differential interference contrast (DIC), second harmonic generation, and interferometric confocal reflectance microscopy to quantify both collagen monomers and fibrils. Previously, Eric has worked at SpectraWAVE (now a part of Phillips) in Bedford, Massachusetts, and Epic Systems in Verona, Wisconsin.
How to get to the talk:
If you would like to drive in, we recommend parking at the Renaissance Parking Garage located at 835 Columbus Avenue, Boston, MA 02120. The parking rates are $28 for 1-2 hours and $34 for 2-3 hours. To get to Dana, you will need to cross over the Ruggles train stop either through the station or over the walking bridge next to the ISEC and EXP building.
If you would like to take public transport, Northeastern is on both the orange line (Ruggles) and green line (Northeastern, Green Line E). Ruggles is also on the Needham, Foxboro, and Providence lines for the commuter rail.